Vertical Flame Resistance Test (Textiles)
ASTM D6413 is the foundational vertical flammability test referenced across major North American industrial workwear standards (including ASTM F1506 and NFPA 2112). A conditioned textile specimen is suspended vertically inside a specialized draft-free cabinet, and a standardized methane flame is applied to the lower edge for exactly 12 seconds.
Key Test Parameters & Verification Metrics
- Apparatus
- Draft-free vertical test cabinet with calibrated methane burner
- Exposure
- 12-second direct flame contact to bottom edge
- Core Criteria
- Afterflame time (seconds), afterglow time, char length (mm/in)
- Typical Pass
- Afterflame ≤ 2.0 s; average char length ≤ 100 mm (4.0 inches); zero melt/drip
- Key Applications
- Industrial FR workwear shells, aramid woven fabrics, modacrylic blends